pub const HOLD_S: f64 = 0.75;Expand description
How long the fall must hold before the cut, s, and the span its speed must be the lowest of:
a barometer’s fitted speed can fall by DROP_FLOOR_M_S and more during the boost and
recover. On the public flights’ logs, the longest such fall inside a burn lasted 0.48 s from
its first sample to the one it recovered at, and the deepest went 63.2 m/s below its top (Lince
and Juno III, measured once in a run not committed); after burnout gravity and drag keep the speed falling. HPR Sim’s
choice: about half again the longest, 0.75 s. On set A’s first 200 synthetic flights the cuts
came 1.08 s to 2.30 s after burnout, 0.33 s to 1.48 s before this rule.